Search: 
Advanced Search
Home  >  Resource Centre  >  What's New  >  Journal Acquisitions
Website Tour

The Industry

Concrete Structures

C+A

Education and Training

Resource Centre
  - What's New
- CCAA Publications
- Image Gallery
- Library
- Multimedia

Media Releases

Public Domain Awards

Events

Sustainability

FAQ's



What's New

Improving the environmental performance of concrete - The case for increased mineral addition in cement.

JOURNAL ACQUISITION DETAILS


Ultimate strength of reinforced concrete beams retrofitted with hybrid bonded fiber-reinforced polymer

Media Type: Article/Story
Article Source: ACI STRUCTURAL JOURNAL Vol 107, no 4 pp. 451 - 460
Series:
Author: WU, Y.-F., YAN, J.-H., ZHOU, Y.-W.
Call Number:
Accession Number: 201007451
Publisher: , Farmington Hills, MI, United States   Publication Date: May - June 2010
Subject:STRENGTHENING OF STRUCTURES; BOND STRENGTH; HONG KONG

Abstract:
The external bonding of fiber-reinforced polymer (FRP) to reinforced concrete members has become a popular method of retrofitting/strengthening concrete structures in recent years. This technology allows the high tensile strength of FRP to be transmitted to the concrete structure through surface adhesion. Surface adhesion that relies on the tensile strength of concrete is known to be weak and unreliable. It results in a poor degree of bonding between the FRP and the concrete members and often induces premature debonding at the bond interface. Such premature debonding has greatly reduced the usage rate of the FRP material’s tensile capacity. One feasible, and probably the only fundamental, solution to this problem is to ensure that the FRP “takes root” in the concrete substrate. The authors have accordingly developed a new technology—hybrid bonded FRP (HB-FRP)—that combines adhesive bonding with a new means of mechanical fastening. A pilot test demonstrated that the bond strength of this new technology was 7.5 times that of a conventional adhesive bond, thus successfully resolving the problem of intermediate crack-induced debonding (IC-debonding) for which “no efficient method is available yet to avoid...” This paper presents the results of an experimental study on the quantification of the ultimate bond strength of HB-FRP retrofitted concrete beams, from which a theoretical model is developed for the design of their members. Keywords: adhesive joint; debonding; failure criterion; interfacial strength; modeling


Loan Request
  Terms and Conditions   Contact Us   Email CCAA   Last Updated:25/01/2009